Sashless Windows Company Limited work to the following standards, regulations and guidelines:

DESIGN AND MANUFACTURE

BS644 : 2003 Timber windows. Factory assembled windows of various types.

TIMBER QUALITY

BS EN942 : Timber in Joinery. General classification of Timber quality (1996).

TIMBER PRESERVATIVE TREATMENT

BS5589 : 1989 Code of practice for Preservation of timber.

AIR AND WATER PERMEABILITY

BS6375-1 : 1984 Performance of Windows - Part 1 Classification for Weathertightness.

STRENGTH TESTING

BS6375-2 Performance of windows - Part 2 : Specification for operation and strength characteristics.

INSULATION

Building Regulations Approved Document L (2002) Conservation of fuel and power in dwellings.

GLAZING QUALITY

BS5713 : Specification for Hermetically sealed flat double glazed units.

GLAZING SAFETY

Building Regulations Approved Document N-Glazing-safety in relation to impact, opening and cleaning: 1998 edition amended 2000.

GLAZING METHOD

We comply with National Housebuilding Confederation (NHBC) and Zurich Municipal requirements.

SECURITY*

BS7950 : Specification for enhanced security performance for casement and Tilt/turn windows for domestic applications.

FIRE ESCAPE*

Buildings Regulations Approved Document B1 Fire Safety: Means of Warning and Escape.

CHILD SAFETY AND SAFETY IN USE*

Building Regulations Approved Document K-Protection from falling, collision and impact.

TRICKLE VENTILATION*

Building Regulations Approved Document F-Ventilation:1995 Edition, amended 2000.

DISABLED ACCESS*

Building Regulations Approved Document M: Access and use of buildings.

*Subject to specification.